Sign In | Join Free | My burrillandco.com
Home > Microfluidic Mold >

Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm

Dongguan Heya Precision Mold Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm from wholesalers
     
    Buy cheap Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm from wholesalers
    • Buy cheap Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm from wholesalers
    • Buy cheap Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm from wholesalers
    • Buy cheap Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm from wholesalers

    Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm

    Ask Lasest Price
    Brand Name : HEYA
    Model Number : HY-601
    Certification : ISO10993
    Price : Negotiable
    Payment Terms : T/T,D/A,D/P,Western Union
    Supply Ability : 800 pcs/week
    Delivery Time : 15-20 work days
    • Product Details
    • Company Profile

    Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm

    Heya Precision: Custom Microfluidic Electroformed Molds For Biochips


    Engineered exclusively for biochip manufacturers, IVD (In Vitro Diagnostic) developers, and life science research institutions, our custom microfluidic electroformed molds are precision-crafted to 1:1 match your 2D/3D drawings (CAD, STEP, IGES, DXF formats). Specialized in replicating ultra-fine micro-channels (5–200μm width/depth) critical for biochips—from nucleic acid detection chips to protein analysis chips—they deliver ±0.001mm tolerance to ensure consistent fluid flow, accurate sample mixing, and reliable diagnostic results.

    Why Heya’s Custom Microfluidic Electroformed Molds Stand Out

    Microfluidic biochips demand molds that solve 3 core pain points ordinary molds can’t address:


    • Micro-Channel Precision Gaps: Off-the-shelf molds often have ≥0.005mm deviation, causing uneven fluid resistance that ruins bioassay data (e.g., false positives in COVID-19 test chips);
    • Drawing Mismatch: Generic molds fail to align with custom biochip geometries (e.g., multi-branch micro-channels, integrated reaction chambers), leading to 20%+ chip 报废率 (scrap rate);
    • Biocompatibility Risks: Low-grade mold materials leach contaminants, compromising sensitive biological samples (cells, DNA, proteins) and invalidating test results.


    Heya solves these by engineering electroformed molds exactly to your drawings and using biocompatible, high-purity materials—turning microfluidic biochip production from a “precision gamble” into a reliable process.

    Core Customization Capabilities for Client-Drawn Biochip Molds

    We tailor every mold to your biochip’s unique microfluidic design, with flexibility to handle even the most complex channel architectures:


    Customization DimensionKey OptionsHeya Advantage
    Client Drawing Support2D (DXF/PDF) & 3D (CAD/STEP/IGES) files; supports micro-channel widths (5–200μm), depths (5–150μm), and layouts (straight, curved, branched, spiral)Free pre-production drawing analysis to optimize channel connectivity (e.g., avoiding dead zones in reaction chambers); 100% drawing accuracy guaranteed
    High-Purity Electroforming MaterialsNickel alloy (99.95% purity, biocompatible), nickel-copper alloy (enhanced wear resistance), gold-plated nickel (for anti-corrosion in harsh buffers)Materials meet ISO 10993 biocompatibility standards—no heavy metal leaching, ensuring safe contact with biological samples (cells, enzymes, nucleic acids)
    Micro-Channel Replication Precision±0.001mm dimensional tolerance; Ra ≤0.02μm surface roughness (for smooth fluid flow)Electroforming technology captures micro-channel details at the nanoscale—ensures every channel’s width/depth deviation ≤0.001mm, eliminating fluid flow inconsistencies
    Biochip-Specific EnhancementsIntegrated air vent micro-holes (prevents bubble trapping), alignment pins (for multi-layer biochip assembly), ultra-thin mold walls (for rapid heat transfer in PCR chips)Custom tweaks to solve biochip production headaches—e.g., air vents reduce assay failure rate by 30% in immunoassay chips

    Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm

    Technical Specs: Built for Reliable Biochip Production

    Our molds are engineered to meet the strict standards of life science applications, with specs that directly impact biochip performance:


    SpecificationHeya Standard for Biochip MoldsImpact on Your Biochip Production
    Micro-Channel Tolerance±0.001mm (width/depth)Consistent fluid flow—ensures uniform sample dilution and reaction kinetics, critical for diagnostic accuracy
    Surface RoughnessRa ≤0.02μm (micro-channel walls)Minimizes fluid friction and cell adhesion—ideal for cell sorting chips or single-cell analysis chips
    Service Life≥50,000 replication cycles (nickel alloy)Sustains mid-to-high volume biochip production (e.g., 10,000+ COVID-19 test chips) without mold wear
    Lead Time18–25 days (prototype); 28–35 days (mass-production)Faster than industry average (40+ days) to accelerate biochip R&D and market launch

    Quality & Compliance for Life Science Applications

    • Biocompatibility Certifications: Every mold material passes ISO 10993-5 (cytotoxicity) and ISO 10993-10 (irritation) tests—safe for use in IVD and research-grade biochips.
    • Precision Validation: Post-production, each mold undergoes 3D laser scanning (accuracy ±0.0005mm) to verify micro-channel dimensions, with full inspection reports provided.
    • Contamination Control: Molds are manufactured in a Class 1000 cleanroom to avoid dust or particle contamination—critical for biochips used in molecular diagnostics.

    Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm

    Who Benefits from Our Client-Drawn Biochip Molds

    • IVD Biochip Manufacturers: For diagnostic chips (e.g., infectious disease tests, cancer biomarker detection) where ±0.001mm channel precision ensures test accuracy.
    • Life Science Research Institutions: For custom microfluidic chips (e.g., organ-on-a-chip, droplet microfluidics) requiring unique channel layouts to support experiments.
    • Biochip OEM/ODM Providers: For high-volume production of standardized or custom biochips, where mold reliability and biocompatibility reduce scrap rates and compliance risks.

    Call to Action

    Need a custom mold for your microfluidic biochip design? Upload your 2D/3D drawing—Heya’s engineers (with 5+ years of microfluidic mold experience) will provide a free DFM (Design for Manufacturability) report (including channel optimization tips) and detailed quote within 24 hours.
    Quality Electroforming Microfluidic Molds For Biochips High Precision ±0.001mm for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Heya Precision Mold Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)